DEFINITIONS

  G9.1-1 Excluded confined spaces
  G9.1-2 Definitions

GENERAL REQUIREMENTS

  G9.2 General Requirements - Initial determination
  G9.3 Prohibited entry
  G9.4 Control of hazards
  G9.5 Confined space entry program

RESPONSIBILITIES

  G9.6 Administration
  G9.7 Supervision
  G9.8 Instruction

HAZARD ASSESSMENT AND WORK PROCEDURES

  G9.9-1 Hazard assessment
  G9.9-2 Visiting employers
  G9.11 Confined spaces - Qualified persons

IDENTIFICATION AND ENTRY PERMITS

  G9.14 Expiration of an entry permit

LOCKOUT AND ISOLATION

  G9.18 Isolation of confined spaces
  G9.18.1 Exemption to restriction on use of valves for isolation
  G9.22-1 Alternate measures - Making submissions
  G9.22-2 Alternate measures for confined spaces - Municipal sewage systems

VERIFICATION AND TESTING

  G9.24 Verifying all precautions
  G9.25 Testing the atmosphere
  G9.26 Procedures and equipment

CLEANING, PURGING, VENTING, INERTING

  G9.27 Cleaning, purging and venting
  G9.29 Notifying WorkSafeBC about inerting a confined space

STAND-BY PERSONS

  G9.34-1 General requirements for a stand-by person
  G9.34-2 Stand-by person for a low hazard atmosphere space
  G9.35 Stand-by person for a moderate hazard atmosphere space
  G9.36 Stand-by person for a high hazard atmosphere space

RESCUE

  G9.39 Notification
  G9.41 Rescue procedures

LIFELINES, HARNESSES AND LIFTING EQUIPMENT

  G9.42 When required
  G9.43 Standards

PERSONAL PROTECTIVE EQUIPMENT AND OTHER PRECAUTIONS

  G9.47 Emergency escape respirator
  G9.49 Removal of oxy-fuel torches and hoses from confined spaces

Guidelines Part 9 - Definitions

G9.1-1 Excluded confined spaces

Issued July 21, 2005, Revised June 18, 2008

Regulatory excerpt
Section 9.1 of the OHS Regulation ("Regulation") states:

"confined space" except as otherwise determined by the Board, means an area, other than an underground working, that

(a) is enclosed or partially enclosed,

(b) is not designed or intended for continuous human occupancy,

(c) has limited or restricted means for entry or exit that may complicate the provision of first aid, evacuation, rescue or other emergency response service, and

(d) is large enough and so configured that a worker could enter to perform assigned work;

Purpose of this guideline
The purpose of this guideline is to identify the types of spaces that WorkSafeBC has determined, as contemplated by the above definition, not to be "confined spaces", and the conditions that apply. Also,it outlines the process for and criteria used in making the determination for other spaces.

Enclosed spaces that are not "Confined Spaces" when certain conditions apply
The definition of confined spaces in section 9.1 of the Regulation permits WorkSafeBC to determine certain spaces, to not be confined spaces for the purposes of the application of Part 9 of the Regulation.

The spaces for which WorkSafeBC will make this determination are those that do not pose the hazards of confined spaces that are addressed by Part 9 of the Regulation. Specifically, there must be absolutely no potential for an atmospheric hazard to exist or develop immediately prior to any worker entering the space, nor any risk of entrapment or engulfment to workers entering the space.

Provided that adequate controls are in place to ensure worker health and safety, a harmful substance (for example, welding fume) may be temporarily introduced into the space as an intended or otherwise understood consequence of work activity without the space becoming a confined space. Controls will be adequate if they are in conformity with the requirements of section 5.55 (Types of controls), and the nature of the substance is such that it will not impair the ability of the worker to escape unaided in the event of failure of the control system.

In these circumstances and the further ones outlined below, the following are spaces that WorkSafeBC has determined not to be confined spaces for the purposes of Part 9 of the Regulation:

  • Swimming pools
  • Crawl spaces under school portables or other non-industrial buildings, with openings to atmosphere allowing for continuous passive ventilation
  • Trenches
  • Attic spaces with openings to atmosphere allowing for continuous passive ventilation
  • Open, unconnected manholes for storm or sewer hook-ups at new construction sites
  • Elevator shafts
  • HVAC plenums and related ventilation ductwork
  • Underwater spaces during occupational diving operations. (Note this exception does not apply to a space that contains an atmosphere, even if access to the space is by an underwater route)

The determination that the above are not "confined spaces" for the purposes of Part 9 of the Regulation is conditional on there being no factor that might give rise to any potential for an atmospheric hazard to exist or to develop prior to worker entry or to unexpectedly develop during any entry or occupation by a worker. Similarly, there can be no factor that may give rise to a risk of entrapment or engulfment within the space.

Risk factors may include

  • Whether the space might contain or might have contained a harmful substance (as defined in section 9.1 of the Regulation)
  • The presence of adjacent piping (as defined in section 9.1 of the Regulation) or other conveyance into the space which may contain a harmful substance
  • The presence of material conveyances into the space
  • Whether the space lacks openings to atmosphere, or otherwise does not allow for continuous passive ventilation
  • Other aspects of the design, construction and use of the space that could give rise to a hazard

Where there is any potential for

  • an atmospheric hazard to exist or develop prior to worker entry, or
  • a risk of entrapment or engulfment developing within the space, or
  • the space to unexpectedly contain an atmosphere other than clean respirable air during any entry and occupation by a worker

then the space is a confined space in accordance with the definition in section 9.1. In such a case the employer must comply with the applicable provisions of Part 9 of the Regulation.

Determination regarding other spaces
WorkSafeBC may determine other types of spaces to be excluded from the application of Part 9 of the Regulation in addition to the spaces listed above. Such determinations will be made based on an evaluation by a committee of WorkSafeBC personnel with expertise in confined spaces.

Persons interested in having WorkSafeBC assess whether a certain type of space should be determined not to be a confined space for the purposes of Part 9 of the Regulation may contact the WorkSafeBC office in their region.

Other hazards to be controlled
Although an enclosed space might not be considered to be a "confined space", it may have other hazards that must be controlled. The other parts of the Regulation still apply and must be considered when planning entry and work in these spaces. Other relevant provisions that the employer needs to consider include:

G9.1-2 Definitions

Issued August 1, 1999; Revised February 11, 2004; Preliminary Revision April 9, 2008

Regulatory excerpts

  • The definition of "confined space" in section 9.1 of the OHS Regulation ("Regulation") is

    except as otherwise determined by the Board, means an area, other than an underground working, that
    (a) is enclosed or partially enclosed,
    (b) is not designed or intended for continuous human occupancy,
    (c) has limited or restricted means for entry or exit that may complicate the provision of first aid, evacuation, rescue or other emergency response service, and
    (d) is large enough and so configured that a worker could enter to perform assigned work;

  • The definition of "high hazard atmosphere" in section 9.1 of the Regulation is

    an atmosphere that may expose a worker to risk of death, incapacitation, injury, acute illness or otherwise impair the ability of the worker to escape unaided from a confined space, in the event of a failure of the ventilation system or respirator

  • The definition of "low hazard atmosphere" in section 9.1 of the Regulation is

    an atmosphere which is shown by pre-entry testing or otherwise known to contain clean respirable air immediately prior to entry to a confined space and which is not likely to change during the work activity, as determined by a qualified person after consideration of the design, construction and use of the confined space, the work activities to be performed, and all engineering controls required by this Regulation;

Purpose of guideline
This guideline provides information to further explain some of the terms that appear in section 9.1 (Definitions) of the Regulation. Matters discussed include

  • Underground workings
  • Restricted means for entry or exit
  • Entering the space
  • High hazard atmosphere
  • Low hazard atmosphere

1. Underground working
The definition for "confined space" in section 9.1 of the Regulation excludes underground workings. An underground working is defined in section 22.1 of the Regulation, as including "any adit, tunnel, underground excavation, chamber, caisson, raise, shaft, winze or natural entry." The exclusion applies while the underground area is under construction. Once construction is complete, the underground area will be a confined space if it meets the criteria listed in paragraphs (a) to (d) of the definition for confined space in section 9.1.

2. Restricted means for entry or exit
To be considered a confined space, a work area must meet all four criteria in the definition. A criterion that often raises questions is paragraph (c), which addresses limited or restricted means of entry or exit that may complicate the provision of emergency response.

Entry or exit refers to crossing the portal between the confined space and the outside work area, but also includes consideration of the routes inside the confined space for gaining access to the work area in the space, or returning to the portal from it.

Criterion (c) lists four types of emergency responses.

  • First aid, which refers to treatment for the purpose of preserving life and minimizing the consequences of injury until medical treatment is obtained, and treatment of minor injuries.
  • Rescue, which involves removing a worker or workers from danger, in circumstances where they have become incapable of removing themselves.
  • Evacuation, which refers to the exit of the entire workforce from the work area in an emergency situation.
  • Other emergency response, which includes scenarios such as firefighting, and hazardous materials spill response.

The issue in paragraph (c) is whether the means of entry or exit "may complicate" the provision of one or more of the four types of emergency response. Some factors to consider for different types of emergency situations are provided below.

First aid and rescue: First aid and rescue are often closely related in practice. First aid includes both injury treatment and preparation of an injured worker for transport on a device such as a spine board, stretcher, sked, or ked. Rescue may involve some initial injury treatment at the site of injury, and will always involve removal of a worker from danger, for example, by use of a transport device, or other means such as a lifeline and harness. When carrying a worker on a transport device the normal practice for the response team is to carry it at about hip level with the arms of the bearers extended downward.

The following are some examples of situations where the means of entry or exit will typically be considered to have complicated the provision of first aid or rescue:

  • A space is so small or configured that there is insufficient room for a first aid attendant to provide injury treatment in the space, or for a worker to be prepared for transport.
  • A space for which the means of exit prevents the use of a first aid transport device, and requires a worker to be removed from the space by other means such as a harness, lifeline, and possibly a lifting device.
  • A space in which any of the following circumstances impede the ability to transport an injured worker:
    • The exit port of the space is narrower than the width of the transport device.
    • The exit port is so constructed that a person carrying the device must put it down in order to get through the port or must pass it to another person through the port.
    • The transport device must be lifted at any time to shoulder height or higher when exiting the space with the injured worker in it. (Such lifting might be needed, for example to get a stretcher over top of a piece of machinery on the way to the exit port, or if the exit port was well above floor level and access on a stairway or ramp was not possible.)
    • The transport device must be inclined at any time to an angle of 45 degrees or more above horizontal. (This might occur, for example, when easing the device up to the exit port and out of the space.)
    • Specialized equipment such as a block and tackle or other equipment is necessary during the exit scenario to lift or direct the transport device.
  • A space with a potentially dangerous atmosphere and a means of entry or exit that is so constructed that first aid or rescue workers wearing self-contained breathing apparatus (SCBA) must remove tanks from their backs at any point when entering or exiting.

Evacuation: Whether or not the means of exit may complicate the evacuation of workers from a space will typically depend on factors such as the potential speed of onset of danger, the number of workers in the space, and the obstacles they may encounter when exiting.

If there is the potential for rapid onset of danger, for example, from release of a flammable or toxic atmosphere into the space, it is essential that exits are sufficiently accessible so that workers can exit the space without any delay, regardless of the number of workers. If the impediments to evacuation would result in any delay then the means of exit will be considered to have complicated the capability to evacuate the space.

On the other hand, a space may be one in which the onset of danger would be slow, for example, where the danger could arise from water flowing through a small diameter pipe into a large space, at such a low rate that any danger to workers would only occur after a considerable period of time. In such cases, it may be safe for workers to evacuate the space over a longer period, as long as the evacuation was done in a timely manner, and the time needed did not compromise the safety of any worker.

Other emergency response services: Depending on the space, other emergency response scenarios could include services such as fire fighting or controlling hazardous material spills. If emergency response workers in these situations would need to wear an SCBA or other personal protective gear, and the means of entry or exit is so constructed that that any of the gear must be removed when entering or exiting, then the provision of the emergency response will have been complicated by the means of entry and exit.

3. Entering the space
Paragraph (d) of the definition for confined space in section 9.1 requires that the area in question be "large enough and so configured that a worker could enter to perform assigned work." A worker should be considered to have entered a confined space when the breathing zone of the worker crosses the plane of the confined space access.

4. High hazard atmosphere
The exposure limits in the Table of Exposure Limits for Chemical and Biological Substances (see OHS Guideline G5.48-1) are not used to define the boundary between a moderate and high hazard atmosphere confined space. Section 1.1 of the Regulation defines IDLH atmosphere as "an atmosphere containing a substance at a concentration which is immediately dangerous to life or health (IDLH) because the concentration is greater than that from which one could escape without any escape-impairing symptoms or irreversible health effects, and includes an atmosphere with an unknown concentration with the potential to be immediately dangerous to life or health."

IDLH levels for specific contaminants are available from sources such as Documentation for IDLH Concentrations, NIOSH May 1994, or may be specified on the MSDS for the substance. An atmosphere meeting this definition would be high hazard under section 9.1. However, the definition of high hazard also covers other situations. In determining whether a confined space contains a high hazard atmosphere, consideration should be given to

  • The space's original atmospheric conditions
  • The contaminants that will be generated by the work to be done in the space
  • The ventilation or other engineering controls applied to remove or reduce the level of contaminants
  • The rate at which the atmosphere will deteriorate on failure of the engineering controls
  • The ability to recognize failure of engineering controls
  • The time required for a worker to leave the space unaided

The atmosphere will generally be classified according to the level of contaminants after the application of engineering controls. However, if on failure of the controls, the level of contaminants may increase at a rate that will prevent the worker from escaping unaided, the atmosphere is high hazard.

5. Low-hazard atmosphere
The definition of low hazard atmosphere includes a reference to a qualified person. Qualified is generally defined in section 1.1 of the Regulation. However, the determination whether an atmosphere is low hazard is part of the hazard assessment required to be done by a qualified person under sections 9.9 and 9.11. Section 9.11 sets out specific requirements for who is a qualified person for this purpose. See also OHS Guideline G9.11.

The definition also refers to "an atmosphere which is shown by pre-entry testing or otherwise known to contain clean respirable air...." Paragraph 9.25(7)(c) states "Pre-entry atmospheric testing is not required in a confined space with a low hazard atmosphere if...prior representative sampling has demonstrated that the atmosphere within the space or group of similar spaces meets the low hazard atmosphere definition." See also OHS Guideline G9.25. This sampling will commonly be the basis for it being "otherwise known" that a space contains clean respirable air.

Back to Top

Guidelines Part 9 - General requirements

G9.2 General Requirements - Initial determination

Issued August 1, 1999; Editorial Revision November 23, 2006

Section 9.2 of the OHS Regulation requires the employer to identify each confined space and determine whether it will require worker entry. Compliance will require a site inspection/survey. The results of the inspection/survey are then used as the basis for action under sections 9.3 to 9.5, depending on whether workers must enter the confined space or not.

Section 9.2 is a specific requirement and supplements the general requirement to inspect the workplace under section 3.5 of the OHS Regulation. The results of an inspection/survey done for compliance with section 9.2 should be documented as required by paragraph 3.3(f) of the OHS Regulation. General workplace inspections, required by section 3.5, should include regular review of the status of compliance with Part 9 Confined Spaces.

G9.3 Prohibited entry

Issued August 1, 1999

Section 9.3 states "If a confined space exists at a workplace but no worker entry is required, the employer must ensure that each point of access to the confined space is secured against entry or identified by a sign or other effective means which indicates the nature of the hazard and the prohibition of entry, and that workers are instructed not to enter".

In some circumstances, use of signs or securing a confined space may be impracticable, for example, for sewer manholes on roadways. Examples of "other effective means" of identification are colour coding and mapping of locations on plans, or using descriptors of covers, manholes and inspection ports in worker education.

The end result should be that workers are able to identify all confined spaces at their workplace, understand the hazards of these spaces and any prohibition of entry. Hazardous areas not intended to be accessible to workers should be secured as required by section 4.34 of the OHS Regulation. For example, a sewer manhole on a road has a cover that is heavy and usually requires a tool for removal, thus it is generally secure against entry by anyone without an appropriate tool to lift the lid off.

G9.4 Control of hazard

Issued August 1, 1999

Section 9.4 of the OHS Regulation states  The employer must ensure that all confined space hazards are eliminated or minimized and that work is performed in a safe manner .

This may require the employer to take measures in addition to the other requirements of part 9. The employer should consider alternative ways of doing the work that avoid or reduce the need to enter a confined space. For example, increasing the interval time between entries to perform routine maintenance in a confined space may be a way to reduce the overall total time workers must work in the space. New methods may eliminate or substantially reduce the need for a worker to enter a confined space. For example, consider an in-place cleaning system for tanks, such as brewery tanks, that flushes and cleans the tanks automatically. If either of these alternatives is practicable, they should be considered.

G9.5 Confined space entry program

Issued August 1, 1999

Section 9.5 of the OHS Regulation requires the employer to have and implement a written confined space entry program before a worker is required or permitted to enter a confined space. The section sets out detailed requirements for the program, which are largely the matters covered by the other sections in part 9 of the OHS Regulation. Aspects that should be addressed in the program and worker training are:

  • a worker in a confined space is to immediately leave the confined space on being instructed by the standby person of a health or safety concern, and
  • adequate procedures for preparing for entry into a confined space (for example, to cover the risk of dangerous contaminants flowing out of the entrance to the confined space when it first opened), as well as procedures for working inside the space.

Paragraph 9.5(c) specifies a list of topics to be addressed, where applicable, for each of the hazards identified under sections 9.9 and 9.10. Subparagraph (x) refers to "coordination of work activities". Coordination will be necessary if there are activities, either inside or outside the confined space that could affect the health and safety of any worker inside the space. Where the activities involve workers of more than one employer, section 3.3 of the OHS Regulation applies, and in the case of a "construction project", section 20.3.

Back to Top

Guidelines Part 9 - Responsibilities

G9.6 Administration

Issued August 1, 1999

Section 9.6 of the OHS Regulation states "The employer must assign overall responsibility for administration of the confined space entry program to a person or persons adequately trained to do so".

The administration of the program required by section 9.5 may be undertaken by the employer's own staff, or it may be assigned to another person or persons. The person(s) appointed responsible for administration of the program must be given the authority and means to ensure the effective operation of the program.

G9.7 Supervision

Issued August 1, 1999

Section 9.7(1) of the OHS Regulation states "The employer must assign responsibility for supervision to a person who is adequately trained to supervise the job before any worker enters a confined space".

Section 9.7 requires the supervision of a worker entering or working in a confined space. Section 9.7(2) describes some specific duties of the supervisor. Section 9.6 requires the employer to assign someone responsible for the administration of the employer's overall confined space program. This division of responsibility may require the program administrator(s) and the supervisor(s) to carry different levels of authority within the program for its efficient operation. The administrator may also fulfill the responsibilities of the supervisor. This may be the case in smaller operations.

G9.8 Instruction

Issued August 1, 1999

Section 9.8 of the OHS Regulation requires that all persons who are "assigned duties or responsibilities related to entry into a confined space must be adequately instructed and trained". Specific training is required for persons contributing to the work activity, even those not entering the confined space, for example, standby workers and rescue workers.

Back to Top

Guidelines Part 9 - Hazard assessment and work procedures

G9.9-1 Hazard assessment

Issued August 1, 1999

The hazard assessment required by section 9.9 of the OHS Regulation must be performed by a "qualified person", as defined under section 9.11. Once the assessment has been done for a specific activity within a particular space or group of similar spaces, it may provide the basis for procedures for every occasion when workers enter those spaces. On each such occasion, the circumstances of the proposed job should be considered beforehand by the supervisor (who need not be a "qualified person" under section 9.11) to ensure that the criteria or conditions upon which the hazard assessment is based remain substantially the same. If the conditions are different in a way that might affect the outcome of the hazard assessment previously done by a qualified person, then the circumstances should be reviewed and entry procedures revised as necessary, by a "qualified person". The assessment of a "qualified person" cannot be changed without the concurrence of the same or another "qualified person".

Paragraph 9.9(2)(b) states that the hazard assessment required under section 9.9(1) must consider a list of specific circumstances as well as "other hazardous conditions". In general, the conditions referred to here represent requirements addressed in other parts of the OHS Regulation. These include, but are not limited to, fall protection, hearing conservation, radiation, heat stress, extreme climactic conditions such as flooding from heavy rains, and lockout of equipment and processes.

G9.9-2 Visiting employers

Issued August 1, 1999

The process of identifying confined spaces, assessing hazards and developing work procedures in a workplace is the responsibility of the employer who operates the business carried on at the workplace. However, employers commonly perform jobs at workplaces that they do not own or control. If an employer is sending a worker to another employer's or owner's operation, the following need to be considered to ensure the "visiting" employer meets their obligations under Part 9.

  1. The visiting employer need not repeat the process of identifying and placing signs on confined spaces as required by sections 9.2 and 9.3 if this has already been done by an effective confined space entry program of the resident employer. The visiting employer should, however, inform its workers of the location and nature of any confined spaces that might affect their work and activities. The owner of a workplace, or the employer controlling a workplace, should provide this information. See also section 118 of the Workers Compensation Act and section 20.3 of the OHS Regulation.
  2. If a visiting employer does work that requires one of their workers to enter a confined space, the visiting employer must have its own confined space entry program under section 9.5. The program may be generic in nature covering the general types of confined spaces its workers would be expected to enter in the course of their visits to different sites. Such generic procedures would then be supplemented by specific procedures for the activity and confined space to be entered, which may be developed in conjunction with the resident employer or site owner. All persons with duties related to confined space entry must be trained in these specific procedures before any entry into a confined space.
  3. If a visiting employer is utilizing some aspects of the resident employer or owner's confined space entry program, the visiting employer has to undertake sufficient hazard identification and risk assessment to ensure their activity will be in compliance if the host employer or owner's confined space entry program is used. For example, a contractor doing welding or painting may create hazards the owner's confined space entry program did not consider in their hazard identification and risk assessment.
G9.11 Confined spaces - Qualified persons

Issued January 1, 2007

Regulatory excerpt
Section 9.11(1) of the OHS Regulation ("Regulation") requires a hazard assessment and written confined space entry procedures be prepared by a "qualified person who has adequate training and experience in the recognition, evaluation and control of confined space hazards"

Section 9.11(2) of the Regulation states "For the purposes of subsection (1)(a) qualifications which are acceptable as evidence of adequate training and experience include

(a) certified industrial hygienist (CIH) or registered occupational hygienist (ROH) with experience in confined space entry,

(b) certified safety professional (CSP), Canadian registered safety professional (CRSP) or professional engineer (P. Eng.), provided that the holders of these qualifications have experience in the practice of occupational hygiene as it relates to confined space entry, or

(c) other combination of education, training and experience acceptable to the Board."

Purpose of guideline
The purpose of this guideline is to provide direction to employers on how to meet their obligations to select qualified persons to create confined space hazard assessments and work procedures. It also provides contact information on some of the accrediting agencies that issue professional certifications referenced in section 9.11.

Employer due diligence
Employers are responsible for selecting qualified persons, as defined in s. 9.11 of the Regulation, to undertake confined space hazard assessments and written entry procedures. The employer must exercise due diligence in the selection of the qualified person. This is especially necessary if the person being engaged does not hold one of the certifications or the license credentials specified in section 9.11(2) (a) or (b). While each case must be considered on its merits, reliance by an employer on a person holding a certification or license specified in section 9.11(2) as being a "qualified person" for the purposes of section 9.11 would normally be considered reasonable, however, due diligence in all cases includes a review of the person's experience as well as their accredited credentials.

Section 9.11(2)(c) permits persons not certified or licensed to be considered qualified for the purposes of this section. Anyone experienced, knowledgeable and capable of doing the required hazard assessments and writing appropriate safe work procedures may be considered to be a "qualified person." The education, training and experience required to complete a particular confined space entry assessment and to write appropriate procedures will depend on the complexity of each situation and the hazards to be controlled.

Factors employers should evaluate in determining whether a person selected to undertake the confined space hazard assessment and entry procedures under 9.11(2)(c) is qualified include:

  • Specific education and training the person has received, and relevance to the industry or type of space the person will encounter
  • Extent of experience with confined space entry relevant to the industry and type of space the person will encounter
  • Experience with specific elements or tasks related to confined space entry, such as:
    • lockout and isolation
    • air monitoring
    • ventilation
    • use of lifeline, harness and lifting equipment
    • the use of personal protective equipment
    • participation in rescue drills
    • previous assessments conducted and procedures written.
  • Proficiency with applying exposure limits

A deficient confined space risk assessment or work procedure may be an indication the person selected was not qualified to do the hazard assessment and/or develop the written confined space entry procedures. In all such situations, whether the person selected purports to be a qualified person under subsection (a), (b) or (c), prevention officers will enquire what steps the employer took to assess the person's qualifications. It should be noted that when evaluating the qualifications of a person who has prepared a hazard assessment and confined space procedures, the officer's primary focus will be the quality of the assessments and procedures rather than the person's credentials.

Where prevention officers encounter hazard assessments and work procedures that are deficient and the person selected meets the definition of "qualified person" in s. 9.11 (2) (a) or (b), the employer who engaged the "qualified person" may file a complaint with the accrediting agency.

Note that in addition to engaging qualified persons, employers are also responsible for ensuring that the confined space hazard assessment contains the required elements, and that the written confined space entry procedures have been developed based on the hazard assessment (see s. 9.9(2) and s. 9.10).

Prevention officers will also assess the extent to which the employer knew or should have known that the assessment and/or procedures were deficient. In particular, prevention officers will enquire into what steps the employer took to ensure that ss. 9.9 and 9.10 were complied with.

Contact with accrediting agencies
Among other things, accrediting agencies often maintain web sites with contact information on accredited persons. For example, the Canadian Registration Board of Occupational Hygienists maintains contact information on persons with ROH's, which can be accessed at http://www.crboh.ca/page.cfm?onumber=1. A list of persons with CIHs can be found on the American Board of Industrial Hygiene web site at http://www.abih.org. Lists of persons with CRSPs, which are issued by the Board of Canadian Registered Safety Professionals, are available at http://www.bcrsp.ca

Back to Top

Guidelines Part 9 - Identification and entry permits

G9.14 Expiration of an entry permit

Issued August 1, 1999

Paragraph 9.14(d) of the OHS Regulation states that an entry permit must identify "the time of expiration of the permit".

An entry permit will cover a specific task or project, which may occur over a number of shifts. The time of expiration of the permit is based on the estimated time to complete the project's work activities and will be identified on the permit. An entry permit should be treated as expired sooner than the stated time of expiration if one of the following occurs:

  • the confined space is placed back in service,
  • continuity in responsible supervision for the confined space is broken, or
  • the task or project is interrupted for a significant time because of an emergency that affects the confined space, such as an accident, rescue requirement, or a breakdown of engineering control equipment.

Once an entry permit has expired, a new permit must be issued before entry into the confined space is allowed.

Back to Top

Guidelines Part 9 - Lockout and isolation

G9.18 Isolation of confined spaces

Issued April 9, 2008

Regulatory excerpt
Section 9.18 (Isolation) of the OHS Regulation ("Regulation") states:

(1) Except as provided in subsection (2), before a worker enters a confined space, adjacent piping which contains or has contained a harmful substance must be controlled by
(a) disconnecting, blanking or blinding, or equivalent engineered system, or
(b) if the adjacent piping contains a harmful substance that is not a gas or a vapour, nor a liquid of sufficient volatility to produce a hazardous concentration of an air contaminant in the discharge of the piping, a double block and bleed system.

(2) If adjacent piping contains or has contained a substance that is hazardous only because of its pressure, temperature or quantity, before a worker enters the space, the pressure must be controlled
(a) to meet the requirements of subsection (1),
(b) provided there is no other pressure source or head pressure, by de-energizing and locking out the pressure source and depressurizing the line, or
(c) by other effective means.

(3) Repealed [B.C. Reg. 243/2006, effective January 1, 2007.]

(4) Except when used in an acceptable double block and bleed system, the closing of one or more valves in a line is not an acceptable means of isolation.

(5) Isolation of a confined space from gases found in a gravity-flow municipal or domestic sanitary or storm sewer system may be accomplished by a p-trap, provided that
(a) the integrity of the trap is ensured immediately upon entry, and
(b) the atmosphere is continuously monitored and shown to contain clean respirable air.

Purpose of guideline
Section 9.18 of the Regulation addresses the isolation of confined spaces from hazardous substances in adjacent piping. Isolation is intended to address hazards arising from fluids (typically liquids, vapours, and gases) and other flowable materials such as slurries, dust, and powders.

The purpose of this guideline is to clarify when section 9.18 applies, and to provide interpretive information for each of its subsections.

Adjacent piping
The definition of adjacent piping in section 9.1 of the Regulation is

"adjacent piping" means a device such as a pipe, line, duct or conduit which is connected to a confined space or is so located as to allow a substance from within the device to enter the confined space;

Under this definition there are two general types of adjacent piping.

  • Piping that is "connected to a confined space," which is piping that has openings in the space creating the possibility of emptying its contents into the confined space.
  • Piping that is not physically connected to the confined space but may be located nearby in a manner that could allow a substance from the piping to enter the space. An example would be a bleed-pipe that may dump contents onto a drain that leads to a pipe connected to the confined space.

Under the definition there are two types of circumstances where piping or conduit in or near a confined space is not adjacent piping.

  • A piping system that passes through the confined space: Such piping would not be considered to be adjacent piping if it is designed and maintained so there are no openings or other locations in the piping where leakage may occur, and work on or around the piping will not cause leakage. In such cases, measures must be adopted under section 9.4 (Control of hazards) to ensure worker safety when working in proximity to the piping. If any work in the space may result in leakage, then the piping must be treated as adjacent piping, in which case the control measures under section 9.18 apply. Leakage could occur for example, during a repair to a piping connection or replacement of a valve stem gland.


  • Orifices between walls: In some configurations there are adjacent spaces with one or more orifices in a common wall between them. Section 9.18 is based on the use of control measures such as blanks, blinds, disconnects, and double block & bleed devices. A wall between two spaces is typically of a width and configuration that the use of such devices is not possible. As such, an orifice in a wall between a confined space and another space is not adjacent piping. Therefore, the blank, disconnect, double block and bleed, and blind requirements do not apply.

    However, the employer must ensure that workers are protected against any hazards associated with orifices under other provisions such as section 9.4 (Control of hazards). The application of section 9.4 means that the potential for fluid discharge into the confined space must be controlled so that the hazards to workers are eliminated or minimized.

    Examples of controls might include a gate over the orifice designed to prevent any leakage and secured in place so that it could not be dislodged from the closed position. For fluids that do not pose a vapour or gas hazard it may be appropriate to use a device to control fluid level in one of the spaces so that it does not rise to and flow through an orifice into the confined space where workers are present.

In the remainder of this guideline the isolation measures permitted under the various provisions of section 9.18 are discussed.

Application of section 9.18(1) - Basic isolation options
This provision specifies three basic options for isolating a confined space: disconnection, blanks, and blinds. It also permits the use of an engineered system that is equivalent to disconnecting, blanking, or blinding.

  1. Disconnection: Means physically disconnecting adjacent piping from a confined space in a manner that prevents its contents from entering the space in the event of discharge. For example, if a pipe is disconnected, either a length of the pipe at least 10 times its diameter should be removed or the open ends of the disconnected pipe should be moved out of line so that leaks will not bypass the disconnection and continue into the confined space. In any disconnect procedure the requirements of the Regulation related to the protection of workers from contents of the piping must be complied with.


  2. Blanking and blinding: Blanks and blinds are defined in section 9.1 of the Regulation as follows:

    "blank" means a solid plate installed through the cross-section of a pipe, usually at a flanged connection;

    "blind" means a solid plate installed at the end of a pipe which has at that point been physically disconnected from a piping system;

    In turn, "blanking or blinding" is defined as:

    ......the absolute closure of adjacent piping, by fastening across its bore a solid plate or cap that completely covers the bore and that is capable of withstanding the maximum pressure of the adjacent piping.

    The goal of a blank or blind is to eliminate any possibility of fluid entering a confined space. Since a conventional blank bisects flanges, if any fluid leakage were to occur it would discharge directly into the atmosphere. Fluid leakage cannot be allowed to pressurize an enclosed area, resulting in possible entry of leakage in the downstream portion of the pipe.

  3. Equivalent engineered systems: For a device to be an "equivalent engineered system" to a blank, blind, or disconnect it must be engineered such that
    (a) any pipe contents leaking past the blocking device (such as a metal plate) is discharged directly to atmosphere
    (b) it is impossible for the pipe contents leaking past the blocking device to become pressurized in an area which will force the leaking contents to re-enter the pipe downstream of the blocking device
    (c) the system is designed on the assumption that seals leak

    Note: Some devices have been designed so they can be used either as a conventional valve, or as a line-blank. To be considered an engineered system equivalent to a blank, the openings to atmosphere around the means of blocking within these devices must be open to the atmosphere at all times, and the adjusting control for the devices must be locked out in the fully closed position when used as blanks. The style of device that requires the openings to atmosphere to be manually uncovered is not an equivalent engineered system.

Application of section 9.18(2) - Materials hazardous only because of pressure, temperature, or quantity
This provision applies to materials that are not toxic or corrosive, and are hazardous only because of pressure, temperature, or quantity. Typically this requirement applies to systems carrying water or steam. Three isolation options are outlined in the requirement

  1. Controls meeting the requirements of section 9.18(1): This provision specifies the options of: disconnecting, blanking, blinding, equivalent engineered systems, and in certain cases a double block and bleed system. The restriction on the use of double block and bleed in section 9.18(1) is not considered to apply to water or steam.


  2. De-energizing and locking out the pressure source: This control option applies to material inside adjacent piping when there is only one pressure source, typically either pressure due to pumps or the head pressure of fluids in lines. The latter is strictly the pressure in the pipe at the confined space location due to the force of gravity.

    For this provision to apply, the layout of the adjacent piping has to be such that if all of the valves are opened with pumps locked out, the fluid would not flow into the confined space. In such cases, then locking out the pumps and depressurizing the line provides sufficient control.


  3. Other effective means: An example of a situation where other means would be considered effective is where in a waterworks system an engineered shutoff float in a chamber is used as a means to prevent water from rising to a height where it would be discharged via a pipe to a confined space. If the rate of flow could endanger workers if the float failed, a monitoring system and means of alerting workers would be needed to warn workers of any failure.

Application of section 9.18(4) - Prohibition on the use of valves
The use of one or more valves as a means of isolation is not permitted except in certain specified cases for substances that are hazardous only because of pressure, temperature, or quantity. If a substance is corrosive or toxic, the use of valves as a means of isolation is not permitted.

There are two circumstances where the use of valves is permitted as a means of isolation

  • Where a double block and bleed system is permitted under section 9.18(2).
  • Certain waterworks systems as permitted under section 9.18.1. (For more information, see OHS Guideline G9.18.1 Exemption on restriction of use of valves for isolation).

Application of section 9.18(5) - Gravity flow sewer systems
A p-trap may be used as a means of isolation if all the following conditions are met

  1. The confined space is being isolated from a domestic sanitary or storm sewer.
  2. The sewer system is gravity flow only at the point of isolation. (The p-trap option does not apply to locations in sewer systems that are pressurized by a pump.)
  3. Work procedures are established that ensure that the integrity of the trap is assessed immediately upon entry.
  4. The atmosphere is continuously monitored while workers are in the space and the atmosphere is shown to contain clean respirable air.

Examples of spaces where this provision could apply include any industrial or sewage system confined space facility that has a sink or other plumbed device that connects to a sewer system.

G9.18.1 Exemption to restriction on use of valves for isolation

Issued April 9, 2008

Regulatory excerpt
Section 9.18.1 (Exemption) of the OHS Regulation ("Regulation") states:

(1) In this section:

"public water supply system" includes valve and meter chambers and pressure reducing stations;

"dam water passageway" includes conduits, pipes, penstocks, power generating chambers, valves and related structures located within storage, diversion or other dams.

(2) Section 9.18(4) does not apply to water piping that is part of a public water supply system if the piping and associated equipment is designed, constructed, maintained and certified by a professional engineer to American Water Works Association standards.

(3) Section 9.18(4) does not apply to a dam water passageway if the structures of the passageway, including a gate valve or other flow control device, are certified by a professional engineer as being safe for workers to enter to perform the intended work.

Purpose of guideline
This guideline provides general information on the application of section 9.18.1, and specific information on each of the two types of exemptions: public water supply systems, and dam water passageways.

Application of section 9.18.1
This provision removes the restriction on the use of valving under section 9.18(4) in the following two circumstances:

  • Public water supply systems that are designed, constructed, maintained, and certified by a professional engineer to American Water Works Association (AWWA) standards.


  • Dam water passageways, as long as the structures of the passageways including valving and other flow control devices are certified by a professional engineer as being safe for entry.

Note that the examples of systems and passageways in the definitions in section 9.18.1 are not intended as comprehensive lists. For example, water mains and piping are not listed in the definition of public water supply systems, but are an integral part of them.

Certifications by engineers under section 9.18.1 will need to be available for review by a WorkSafeBC Prevention officer, where necessary to assess compliance with the requirements.

Information on each of the two types of circumstances in which the exemption applies is provided below.

Public water supply systems: The exemption applies to systems that provide water for domestic uses such as human consumption, food preparation, and cleaning purposes. It also applies to water distribution networks for fire suppression, which are typically an integral part of public water supply systems.

Note: In some cases, public water will be used downstream for industrial uses, for example in a process industry or a manufacturing facility. The exemption does not apply to such industrial systems. In these circumstances new hazards may be introduced, such as high pressures, temperature extremes, chemical additives, and the use of confined spaces that present hazards other than just water flow.

For a public water supply system to be covered by the exemption, the certification by an engineer is expected to address the design, construction, and maintenance of the system. It would typically be based in part on drawings, specifications, and records of installation and maintenance of components of the system. A significant element would be the assessment of current performance. The applicable information would be evaluated against AWWA standards. When issuing the certification, the professional engineer should specify the time period for which the certification would apply.

The AWWA maintains information on its standards at its web site, which can be accessed at http://www.awwa.org. The AWWA provides full print and CD-Rom sets of standards, as well as a selected set for small water systems. The AWWA has developed a substantial number of standards, only some of which would likely apply in specific situations. Many AWWA standards are also recognized by the American National Standards Institute (ANSI).

If a water supply system was constructed to a recognized standard other than AWWA (or ANSI where applicable), WorkSafeBC can consider accepting the alternate standard under the terms of section 4.4(2) of the Regulation. For a system installed before a recognized standard was in place, then an application can be made to WorkSafeBC for acceptability of the system under section 4.4(1).

Dam water passageways: The application of the exemption under section 9.18.1 is restricted to dam water passage ways. At a dam and associated hydroelectric station there may be a number of confined spaces, for example, fuel storage tanks, which are not part of the dam water flow system, and for which the exemption would not apply.

For confined spaces in which the exemption applies, engineering certifications specifically need to address the issue of worker safety. Such certifications are expected to be time limited, and the engineer will need to make the determination of applicable time period as part of the certification procedure.

G9.22-1 Alternate measures - Making submissions

Issued August 1, 1999; Editorial Revision October 2004; Editorial Revision February 7, 2006; Editorial Revision June 6, 2006; Editorial Revision June 22, 2007; Revised April 9, 2008

Regulatory excerpt
Section 9.22 (Alternate procedures) of the OHS Regulation ("Regulation") states:

(1) If isolation using the measures specified in section 9.18 is not practicable, the employer may implement alternate measures acceptable to the Board.

(2) All workers affected by measures implemented under subsection (1) must be informed of the measures taken and instructed in any applicable work procedures.

Purpose of guideline
This guideline outlines who an employer should contact at WorkSafeBC to determine if alternate measures under section 9.22 of the Regulation are acceptable, and the types of information to include in the submission. It also provides information on how WorkSafeBC will issue its decisions.

This guideline is the first in a series of guidelines on section 9.22. Additional guidelines outline frameworks for developing submissions on alternate measures in specific situations.

Contacting WorkSafeBC for acceptance of alternate measures
If an employer develops a set of alternate measures for a type of confined space covered by one of the framework guidelines in the G9.22 series, they should contact the Regional office of WorkSafeBC to determine acceptability. The applicant may be an employer who owns or operates the confined space, or may be a contractor doing work on or in it.

If an employer wants to implement alternate measures in circumstances that are not covered by one of the framework guidelines in the G9.22 series, the employer will need to contact the Regulatory Practices Department of the Worker and Employer Services Division of WorkSafeBC.

Note: In some cases a framework guideline may include a set of alternate measures considered to be acceptable in a specific situation. If an employer has workers who would be entering a confined space, or group of spaces, that would fall within the identified situation, and wishes to use the set of measures as an alternate means of isolation they may do so without the need to contact WorkSafeBC for an acceptance. Where such measures are included in a guideline they will be set off by a framed border.

What to include in the submission
A submission may cover a single confined space or a group of confined spaces that share similar characteristics. It should focus on the issues associated with isolation of the confined space, and cover the elements outlined below.

Main elements of the submission
The submission should address matters including

  1. A brief description of the space, or the group of confined spaces with similar characteristics for which the submission is made
  2. Why isolation using the measures specified in section 9.18 of the Regulation are not practicable
  3. Contact information for the person who administers the confined space program, and for the qualified person who conducted the hazard assessment and prepared the alternate measures
  4. A description of the hazards to be addressed by the alternate measures
  5. The alternate measures that will be used to address the hazards, and how workers will receive protection from the hazards through use of the measures
  6. How workers who are required to use the proposed measures will be informed of the measures taken and instructed in the applicable work procedures, as required by section 9.22(2)
  7. How use of the alternate measures will be supervised
  8. The time period for which the alternate measures will be needed

The submission should also include information from the joint OHS committee, or worker health and safety representative, as applicable, indicating their comments on the proposal, or other information that indicates the affected party has been consulted on the alternate measures. (Section 9.11(1)(b) of the Regulation requires consultation with these parties on confined space hazard assessment and written procedures.)

Information needed for Element #4 - hazards to be addressed
Hazards associated with the isolation of the confined space typically involve those arising from fluids such as liquids, gases, and vapours, and other materials such as slurries, dusts, and powders that could flow into the space. The submission should address matters such as the following, where applicable:

  • Potential for material to flow into the space
  • Characteristics of the material including pressure, temperature, quantity, toxicity, and corrosive properties
  • Other hazards associated with the flow of material into the space, such as slips and falls, electric shock, reduced visibility, moving machinery, or equipment
  • Review of historical air monitoring for site (if available and applicable)
  • Any potential for work being done in the space to contribute to the likelihood of material flow into it

Information needed for Element #5 - alternate measures to be used
The measures chosen should be based on careful consideration of the hazards, and provide the most effective means of dealing with them. The submission should cover matters such as the following, where applicable:

  • Engineered means of controlling flow, and related procedures
  • Ventilation, where applicable, to ensure that hazardous gases, vapours, and other air contaminants from adjacent piping are kept below exposure limits, and no circumstances immediately dangerous to life and health, including oxygen deficiency, could occur
  • Atmospheric testing, where applicable, if air contaminants could enter the space from adjacent piping while the space is occupied
  • Monitoring of flow rates of materials and/or levels in the confined space
  • The method of communication between a person or system for monitoring material flow and entry workers
  • Emergency and rescue procedures in the event of any isolation system failure

Issuing a decision
Decision made by a WorkSafeBC Prevention officer: Where the circumstances of the confined space(s) for which the application is made are addressed by one of the framework guidelines in the G9.22 series, a Prevention officer responsible for the firm may make the decision on behalf of WorkSafeBC. As needed, the officer may contact Engineering or Regulatory Practices for advice. The officer will record their decision, including the terms of the decision and time period for which it is issued, in the text of an inspection report for the firm. The officer will provide a copy to the employer, who must post a copy at the worksite as required by the Regulation. Once the decision is made, the officer will forward the request and decision to Regulatory Practices.

Decision made by Regulatory Practices: Where an application for acceptance involves a situation not covered by a framework guideline in the G9.22 series, Regulatory Practices will issue the decision to the applicant using the standard format for Acceptance Request (AR) decisions. The applicant will post a copy of the decision and ensure copies are distributed to workplace parties, as required by the decision. Copies will be sent to the WorkSafeBC Regional Prevention manager and Prevention officer responsible for the firm, and to others who contributed information to the decision-making process.

Note: All decisions will focus on the issue of alternate measures for isolation of the confined space under section 9.22 of the Regulation. They will not, as a rule, address the issue of compliance with other provisions of the Regulation and must not be taken as an endorsement of the overall confined space program for the site.

G9.22-2 Alternate measures for confined spaces - Municipal sewage systems

Issued April 9, 2008

Regulatory excerpt
Section 9.22 (Alternate procedures) of the OHS Regulation ("Regulation") states:

(1) If isolation using the measures specified in section 9.18 is not practicable, the employer may implement alternate measures acceptable to the Board.

(2) All workers affected by measures implemented under subsection (1) must be informed of the measures taken and instructed in any applicable work procedures.

Purpose of guideline
This guideline outlines some issues to consider when developing alternate measures for municipal storm and sanitary sewage systems under section 9.22(1), where the isolation of adjacent piping under section 9.18 is not practicable.

Among other things, the guideline discusses

  • How to make submissions on alternate measures to WorkSafeBC for circumstances covered by the guideline
  • General hazard and control issues that can arise throughout sewage systems
  • Information specific to three parts of sewage systems: piping, pumping stations and treatment plants

This guideline should be used in conjunction with OHS Guideline G9.22-1, which outlines elements that need to be addressed in any submissions to WorkSafeBC. Also, note that OHS Guideline G9.18, which provides interpretive information on terminology used with isolation procedures, may be of assistance.

NB. None of the information in this guideline is to be used as a substitute for the conduct of a site specific hazard assessment and development of associated safe procedures by a qualified person, as required under sections 9.9 - 9.11 of the Regulation.

Making a submission
A submission may cover a single confined space or a group of confined spaces that share similar characteristics. After developing proposed alternate measures for a space or spaces in a municipal sewage system, the employer will need to contact the local Regional office of WorkSafeBC to have the procedures reviewed by a WorkSafeBC Prevention officer for acceptability.

The focus of any submission on alternate measures should be on the fluids (including liquids, gases, and vapours), and other flowable materials that would be controlled by the isolation measures listed section 9.18.

For other land-based sewage systems, such as industrial systems which are not connected to municipal sewers, submissions should be made to the Regulatory Practices Department of the Worker and Employer Services Division of WorkSafeBC in Richmond. Note: the next guideline in this series (G9.22-3) discusses alternate measures for confined spaces on ships and other vessels that are undergoing repair or maintenance. Confined spaces on such vessels are likely to include on-board sewage systems.

General comments on hazards and alternate control measures in sewage systems
1. Hazards

For any sewage system, storm or sanitary, hazards that can be encountered include engulfment or immersion, exposure to toxic gases or vapours, oxygen deficiency, flammable atmospheres, slipping or tripping hazards, and electrical hazards where energized conductors or electrical equipment are exposed to damp conditions or liquid contact.

The potential for immersion will vary depending on factors including the frequency and volumes of discharges to the system, precipitation, and the relationship between the rate of possible fluid flow into the confined space to the dimensions of the space. For example, if the space is relatively small, and the diameter of inlet piping is substantial, there may be a relatively high potential for immersion. The contrary is the case where the floor area and volume of the space is large relative to possible fluid flows into it.

Water in sewage systems may be contaminated by materials such as oils from roadway runoff or industrial discharges, and in some cases materials such as ferrous chloride or other substances may be added for purposes of corrosion or odour control.

Air contaminants of concern in sewage systems include hydrogen sulfide, carbon monoxide, carbon dioxide, methane, ammonia, and organic vapours from oils or fuels that have entered the systems from roadway runoff. Decomposition gases such as hydrogen sulfide and methane can be a particular issue where sludge and other organic matter have been allowed to accumulate, and can be off gassed, particularly when the materials are disturbed. The term "sewer gas" is often used to refer to gases in sewage systems. It is an imprecise term, sometimes used in reference to hydrogen sulfide, but also to the complex mixture of gases that can be present.

In sanitary sewage systems, fluids may contain waterborne organisms that may cause disease (for example, hepatitis, giardiasis, and leptospirosis). Diseases affecting the gastrointestinal or respiratory systems have been reported among sewage workers.

Hazards from exposure to fluids and gases in piping may be complicated by other issues such as restricted visibility, limits to communication, and distance from exit points.

2. Alternate control measures
Various aspects of alternate control measures are discussed below, from fluid control to instruction and training.

  • Fluid control: In some cases fluid flow can be controlled in sewage systems.
    Examples of fluid control techniques are
    • Inserting inflatable rubber bladders into pipes
    • Cutting into pipes to install removable sealing devices
    • Closing valves or gates
    • Installing mechanical blocking devices that consist of double seals designed so that the space between the seals may be monitored or pressurized to greater than the pressure of the hazardous fluid
    • Directing fluid flows through piping or channels adjacent to the space in question
    • Freezing of the pipe contents to form a plug in the pipe
    • Performing work when events such as tides ensure that the fluid level does not present a hazard

    The choice of method for fluid control will depend on what is feasible in the situation. In all cases the basic principle is that the most effective of the feasible methods should be chosen. Wherever manufactured devices are used, manufacturer's instructions and safe work practices must be followed. For example, the safe use of bladders will typically include measures such as cleaning the piping into which the bladder is placed, inflating the bladder only to permitted pressures, and securing the bladder so that it is not displaced in the pipe by a build up of pressure behind it.

    If devices that control the fluid flow are capable of being locked out then the requirements of Part 10 (De-energization and lockout) of the Regulation apply.

    The analysis of valves as a control measure should assume that all valves leak. However, there is no expectation that a properly installed and maintained valve will fail catastrophically if no work is being performed on it.

  • Leakage of liquid and pumping: It is recognized that systems will often permit some leakage, and in that event, a means of pumping out the fluid may be necessary. A means of monitoring leakage coupled with procedures for evacuation in the event leakage rates or fluid levels exceed safety criteria is often a necessary feature of the safety system. Liquid level alarms or visual checks may be required to monitor liquid levels. It may be possible to set up a leakage check system from a central control location using camera monitors or other means.


  • Air monitoring and ventilation: The historical record of atmospheric testing inside of the confined space needs to be considered along with the recent physical condition of the space. For instance, historical atmospheric testing during conditions of normal fluid flows may have not indicated atmospheric hazards. However, a space that has been left stagnant may have allowed material to decompose and create atmospheric hazards. The use of personal air monitors or other means of continuous monitoring will assist with worker safety where there is the potential for air contaminants to be present.

    Ventilation must be adequate, and be provided in conformity with the requirements in Part 9 (Confined spaces) of the Regulation.


  • Communications: A means of communication with workers in the confined space will need to be provided and periodically verified as being effective.


  • Personal protective equipment: Workers must be supplied with and use appropriate personal protective equipment as required by the Regulation to protect against hazards that cannot be eliminated.


  • Slipping, tripping, and electrical hazards: Sewage systems are typically damp or wet environments, and appropriate measures must be taken regarding slipping, tripping, and electrical hazards. If fluid entering the confined space conceals trip and fall hazards such as floor holes or openings, these hazards need to be addressed, as well as any hazards involving the potential for liquid contact with energized conductors and equipment.


  • Evacuation planning: Where there is a danger from the uncontrolled entry of liquid into the confined space, the time required to evacuate workers from the confined space needs to be shorter than the minimum possible time it would take fluid entering the confined space to create a condition that would impede exit from it. In general, the time is calculated using the maximum possible flow from the pipes that could be created by the failure of any single system element, and the relationship of that flow to the floor area of the space. The time required for evacuation should make allowance for possible problems during evacuation. The number, location, and types of exits are relevant in determining the evacuation time. Means of access and egress should be made as convenient as possible.

    It is recognized that in some cases catastrophic failure of the control system could lead to immediate danger to workers from fluid flow. For that reason isolation measures need to provide a high level of assurance that such circumstances will not occur. Evacuation measures need to be designed to minimize the time needed to exit, and rescue plans must be in place.

    Evacuation times in the event of development of harmful atmospheres may be more difficult to predict, and steps must be taken to ensure that personal protective equipment and rescue measures are up to the task. Depending on the potential exposure, workers in the confined space may be required to be permanently attached to a lifeline.


  • Instruction and training: All workers affected by alternate measures must be informed of the measures taken and instructed in any applicable work procedures, including emergency measures. Workers also need to be informed of any residual hazards not fully controlled by other measures.

    Some considerations are provided in the remainder of this guideline for three typical parts of sewage systems: piping, pumping stations and sewage treatment plants.

Specific comments on piping, pumping stations, and treatment plants
1. Storm and sanitary sewage piping

When a worker enters a sewage pipe, the pipe itself is the confined space, not "adjacent piping" from which the space must be isolated as required by section 9.18. However, the feeder pipes that discharge into the pipe that is entered can be considered to be adjacent piping.

Often in such cases it may be impracticable to isolate the adjacent piping. In some cases partial or complete isolation may be possible with temporary dams, inflatable bladders, or other means such as rerouting of fluid flow.

However, in most cases alternate measures to ensure worker safety will involve a set of occupational hygiene and safety precautions other than or in addition to isolation.

When dealing with piping systems, there may be limits on the practicability of some standard occupational hygiene control measures. For example, ventilation as a means of assuring a safe atmosphere may not be practicable if the work must be done over a length of the piping system a substantial distance away from access points. However, wherever ventilation is feasible, it should be used, and it must always be provided where required by Regulation. If ventilation cannot assure a safe atmosphere, reliance may need to be placed on air monitoring and respiratory protection, including air supplied respirators where the circumstances warrant.

Hazards in piping will vary somewhat depending on whether the piping is a storm or sanitary sewer, or both. Often the piping will carry both storm and sanitary sewage in a combined system.

Sanitary sewers will have hazards associated with organic matter, including biological hazards, as well as air contaminants such as hydrogen sulfide or methane from the decomposition of organic matter. Such gases may be particularly an issue where sludge and other materials have been allowed to accumulate, and are subsequently disturbed. Where sewage flows at a rate of 2-3 feet per second (2-3 km/h) sedimentation and sludge build up is less likely. However, in such cases blockages can still occur where objects impede flow, or the diameter of the piping is an issue.

Flow volumes and rates will vary according to sewage discharge patterns in the catchment area and precipitation. Predicting patterns of flow will assist with worker safety.

Storm sewers will typically include hazards associated with water flows, which will vary with precipitation and drainage patterns in the area. Drainage from streets and parking areas is likely to be contaminated with oil and other hydrocarbon residues from vehicles. Also, where access locations to the sewers are in proximity to idling vehicles, for example at intersections and parking areas, there is the potential for exposure to exhaust gases including carbon monoxide.

Both sanitary and storm sewers may be contaminated with industrial or household chemicals, and with potentially harmful objects such as needles.

2. Sewage pumping stations
For pumping stations that are confined spaces the adjacent piping will typically be the sewer lines that feed into a reservoir or sump and the pipes used to discharge the sewage. There may also be drains that are arranged so that the contents of the drain could enter a sump and merge with the general sewage flow. Gases must be considered as well as liquids. Various means of controlling fluid flow may be possible. Given the proximity to a point of access, and the limited space involved, it should always be possible to provide effective ventilation into a pumping station.

The timing of events must also be considered in the hazard analysis. For instance the level and composition of off-gassing may depend on how long it has been since a channel or pipe has been emptied of residue. It may also be affected by the extent of liquid agitation and the surface area in contact with the atmosphere in partially filled pipes.

Knowledge of historical flow patterns and contamination problems could be of assistance in performing the required hazard analysis. Anticipated weather patterns may also affect the scheduling of the work inside of the confined space in order to minimize worker exposure to hazards of fluid flow.

3. Sewage treatment plants
Many of the hazards from fluid flow in sewage treatment plants are similar to those encountered elsewhere in sewage systems. Treatment plants offer certain advantages in terms of hazard control given that work activities occur at fixed sites and often above ground. The design of the system at the site may help ensure that the need for alternate measures is minimized.

Some of the hazard issues at the plants include chemicals used to treat sewage, potential for exposure to tidal water for facilities on the coast, and hazards arising from the treatment system. For example, the potential for hydrogen sulfide and methane to develop from the decomposition of organic material may be a particular issue in desludging operations in secondary sedimentation tanks, on the tops of sewage digesters, and in any tanker loading or unloading operations.

Sewage treatment plants may have channels that are connected by orifices or weirs. Such connections are not necessarily "adjacent piping." However, any hazards created by these adjacent channels need to be addressed. The hazards to workers from entry into channels will vary somewhat depending whether or not the channels are open or closed.

A means of fluid control that is possible in some circumstances is to channel fluid flow around the space in which worker entry is required. Alternate fluid control measures that can be used include sealing devices that are installed through holes drilled in the side of pipes and inflatable bladders. In such cases ensure that the manufacturer's instructions and other necessary safe procedures are followed.

Where discharge occurs into tidal water it may be possible to plan the timing of work so that ocean tides do not create a liquid hazard from the outlet side.

Guidelines Part 9 - Verification and testing

G9.24 Verifying all precautions

Issued August 1, 1999

Section 9.24 of the OHS Regulation states "Before a worker enters a confined space, pre-entry testing and inspection must be conducted to verify that the required precautions have been effective at controlling the identified hazards and that it is safe for a worker to enter".

Section 9.25 of the OHS Regulation requires the atmosphere in a confined space to be tested in a number of circumstances before a worker enters the confined space. The requirements of section 9.24 are not limited to atmospheric testing. Other hazards, such as entrapment, radiation, heat stress, noise and cold stress may also be present. These require assessment regarding the degree of risk to workers.

In addition, it is necessary to inspect before entry to ensure that all required controls are in place. These are similar to requirements for supervisor responsibility stated in section 9.7(2).

G9.25 Testing the atmosphere

Issued August 1, 1999; Revised November 17, 2003

Additional testing

Section 9.25(4) of the OHS Regulation states "While a worker is inside a confined space with a moderate or high hazard atmosphere, additional testing must be conducted as necessary to ensure the worker's continuing safety".

The intervals at which additional testing should occur depends on the outcome of the hazard assessment, the operations being performed in the space and the risk of the atmosphere changing substantially. In addition, the selection of appropriate instrumentation for testing of the space, together with the requirement of section 9.25(5) for continuous monitoring, may determine the frequency of testing that is practicable.

Continuous monitoring

Section 9.25(5) states "Whenever practicable, continuous monitoring of the atmosphere must be done".

"Practicable" is defined in section 1.1 of the OHS Regulation as meaning "that which is reasonably capable of being done". In determining what is "practicable", the relevant factors include:

  • the availability in the marketplace of continuous monitoring devices,
  • the reliability of continuous monitoring devices to detect contaminants within acceptable ranges to provide worker protection (this means in the range of the exposure limit or lower), and
  • the potential for cross contamination or poisoning of the sensors for the instrumentation selected.

Low hazard atmospheres

Section 9.25(7) permits entry into low hazard atmospheres without pre-entry atmospheric testing if the conditions listed in paragraphs (a) to (d) are met. Condition (c) is that "prior representative sampling has demonstrated that the atmosphere within the space or group of similar spaces meets the low hazard atmosphere definition".

"Representative sampling" is acceptable if the sampling data is

  • statistically significant,
  • provides for the reliable determination of worker exposure, and
  • obtained in accordance with the confidence limits stated in OHS Guideline G5.48-9.
G9.26 Procedures and equipment

Issued August 1, 1999

Section 9.26(4) of the OHS Regulation states "Test results, other than continuous monitoring results, must be posted without delay at all points of entry to the confined space".

Continuous monitoring provides continuous feedback to the personnel entering and working in the confined space. In effect, this provides better feedback than the posting of test results at all entrances to the confined space. However, the section does not exempt the employer from recording continuous monitoring test results at appropriate intervals as required by section 9.26(3). Many instruments used for this purpose are equipped with a data logging capability that makes it easy to record test results and to interpret the data. Otherwise, readings can be manually recorded at appropriate time intervals.

Keeping records of continuous monitoring will be particularly important for employers wanting to eliminate pre-entry atmospheric testing for a low hazard atmosphere confined space, as it may be a source for the data required by paragraph 9.25(7)(c).

Back to Top

Guidelines Part 9 - Cleaning, Purging, Venting, Inerting

G9.27 Cleaning, purging and venting

Issued August 1, 1999

Section 9.27(1) of the OHS Regulation states "When practicable, the employer must ensure that a confined space to be entered contains clean respirable air". Section 9.27(2) states "If a confined space is known, or shown by pre-entry testing to contain other than clean respirable air, the hazard must be controlled by cleaning, purging or venting the space and the atmosphere must be retested before a worker enters the space".

More than one cleaning, purging or venting may be required to achieve a confined space with clean respirable air. It depends on what is practicable and reasonable in the circumstances. If continued cleaning, purging or venting will further the objective of having a clean respirable atmosphere, these processes should be repeated. If continuing these processes will not effectively improve the residual atmospheric quality, then the employer may proceed with entry in accordance with section 9.28 of the OHS Regulation.

G9.29 Notifying WorkSafeBC about inerting a confined space

Issued August 1, 1999; Revised May 9, 2006

Regulatory excerpt
Section 9.29 (Inerting) of the OHS Regulation states:

(1) The employer must notify the Board in writing, and submit a copy of the proposed work procedures, at least 7 days before a worker enters a confined space which has been inerted.

(2) The employer must follow any additional precautions that are prescribed by the BoardBoard after review of the notification.

(3) If a confined space has been inerted

(a) all entry precautions for high hazard atmospheres must be followed, except the requirement for continuous ventilation,

(b) every worker entering the confined space must be equipped with supplied-air respiratory protection meeting the requirements of Part 8 (Personal Protective Clothing and Equipment),

(c) all ignition sources must be controlled, and

(d) the atmosphere inside the confined space must remain inerted while workers are inside.

(4) Subsection (1) does not apply to entry for the purpose of performing emergency rescue duties.

Purpose of guideline
This guideline provides information for employers on how to notify WorkSafeBC prior to inerting a confined space, and the types of information to include in the submission. It also provides information to WorkSafeBC prevention officers to assist with reviewing applications.

How to notify WorkSafeBC
Section 9.29(1) of the OHS Regulation requires an employer to notify WorkSafeBC in writing of an intent to enter an inerted confined space, and to submit a copy of proposed work procedures at least seven days before entry. As noted in section 9.29(4), this obligation does not apply if the entry is in an emergency situation for the purpose of performing rescue duties.

Information can be sent by post, FAX, or by e-mail. However, regardless of the means of communication, the written communication must be received by WorkSafeBC at least seven calendar days before planned entry. It is not sufficient to call WorkSafeBC seven days or more before entry and then submit the written request in less than the required time.

The request should be sent to the nearest WorkSafeBC office, to the attention of the Prevention Regional Manager, or to the Occupational Hygiene Officer responsible for the worksite where the entry will occur. Notifications often arise from refining and fuel manufacturing operations in the oil and gas sector. Typically such operations are found in Northeast or Northwest BC, or in the Lower Mainland. For these locales, inspectional programs are handled, respectively, from the Prince George, Terrace and the Burnaby/Coquitlam offices of WorkSafeBC.

Information on how to contact offices of WorkSafeBC is found on the web site at www. worksafebc.com. Click on the "Contacts" button on the home page. Or alternatively, the information is available by calling the Prevention Information Line at 604-276-3100, or toll free in BC at 1-888-621-7233.

Preparing the submission
While section 9.29 of the OHS Regulation deals with requirements specific to inerting, other requirements of Part 9 (Confined spaces) also apply. Of central concern is that the necessary hazard assessment has been done and associated work procedures developed, as required by sections 9.9 to 9.11. Under these provisions the hazard assessment and work procedures must be prepared by a qualified person(s) and, as applicable, the joint occupational health and safety (OHS) committee or worker OHS representative must be consulted.

The work associated with inerting is often highly specialized, and may involve the services of a contractor. Where a prime contractor or owner arranges for a contractor to conduct the work, then the contractor's joint OHS committee or worker OHS representative will need to be consulted. Where workers of the prime contractor will be engaged in any of the work associated with the confined space, for example, in preparation of the space, work in it or in an emergency rescue, then consultation with the prime contractor/owner's joint OHS committee or worker OHS representative will also be needed.

To permit proper assessment by WorkSafeBC, the submission will need to include the following:

  • The worksite location and specific identity of the confined space, and the date of intended entry.
  • The identity of the qualified person(s) who prepared the hazard assessment and work procedures, the confined space entry program administrator, the person supervising the job and, where applicable on a multi-employer site, the person coordinating work activities.
  • Information on consultation with the joint OHS committee or worker OHS representative, as applicable, on the hazard assessment for the confined space and associated work procedures.
  • The written hazard assessment of the confined space to be inerted. The assessment, which is key to developing safe work procedures, will address the factors outlined in section 9.9 of the OHS Regulation, including any factors related to inerting, such as the presence of any pyrophoric (spontaneously flammable), oxidizing, flammable or other reactive materials, and any sources of ignition.
  • Written work procedures for entry and work in the confined space, which specify the means to eliminate or minimize all hazards likely to be present. Procedures also will need to address the safe removal of any waste material and the installation of any replacement material, as applicable. The procedures must also be in compliance with the four conditions outlined in section 9.29(3) related to
    • precautions for high hazard atmospheres
    • supplied-air respiratory protection
    • control of ignition sources
    • the necessity that the inert atmosphere will be in place for the entire time that workers are inside the confined space
  • Material safety data sheet(s) or hazardous waste profile sheet(s) for any waste material to be removed from the space.

Reviewing the submission
The assigned prevention officer will be responsible for reviewing the application and making a determination of any concerns or issues with the proposed procedures to be addressed by the applicant. Precautionary information should be entered into inspection text on an Inspection Report and communicated to the employer prior to entry. Where work is being done by a contractor, both the prime contractor and contracted employer will need to be advised.

To assist with the review, the officer may wish to examine previous decisions related to inerting confined spaces, or consult with persons who have been involved with such decisions. This may include the Occupational Hygiene Variance Coordinator or Senior Occupational Hygienist, the Senior Prevention Adviser or, as applicable, other prevention officers and the Regional Manager. Consultation may be particularly appropriate in circumstances such as reviewing procedures for types of spaces not previously considered by WorkSafeBC.

If the applicant is a visiting contractor, it may be necessary for the contractor to do a final hazard assessment after arrival on site. It is expected in such cases that the assessment process will ensure that all significant hazards are addressed in the submission to WorkSafeBC, and that a final hazard assessment would only be for the purposes of fine tuning work procedures on minor issues. The hazard assessment and work procedures submitted to WorkSafeBC should be as specific as possible to the conditions on the site where the work will be done.

For example, if the contractor had previously done inerting work in a confined space, then the assessment and procedures should, at minimum, be based on the specific circumstances of that previous work, coupled with any adjustments arising from additional information received from the prime contractor or owner prior to the present job. Any final minor adjustments to the hazard assessment and procedures will be done by a qualified person in consultation with workplace parties, as required by section 9.11.

The prevention officer may, in these or other circumstances, attend the site prior to the confined space being inerted.

Copy to Regulatory Practices
Once the officer's review is complete, materials will be entered into a firm file following normal procedures. A copy of the submission, any additional relevant materials, and the officer's determination regarding the need for further precautions will also be forwarded to the Regulatory Practices Department of WorkSafeBC.

Back to Top

Guidelines Part 9 - Stand-by persons

G9.34-1 General requirements for a stand-by person

Issued August 1, 1999

Sections 9.34 to 9.36 of the OHS Regulation require that, whenever a worker enters a confined space, another worker or workers must be assigned as the standby person(s). The positioning and functions of the standby person differ, depending on whether the atmosphere in the confined space has been determined through the hazard assessment under section 9.9 to be low, moderate or high.

Depending on the rescue procedures, a stand-by person may also be trained and serve as a rescue person for the purpose of sections 9.37 to 9.41(3) of the OHS Regulation. In accordance with section 9.41(3), the stand-by person may not enter the space to effect rescue until at least one other worker is present and prepared to render assistance to the rescue worker.

G9.34-2 Stand-by person for a low hazard atmosphere space

Issued August 1, 1999

The requirement for low hazard atmosphere confined spaces in section 9.34 allows the stand-by worker to effectively serve as a person-check for a worker working alone in the space. The standby person does not have to be located at or near the entrance to the space if there is a "continuous means of summoning the standby person". However, the standby person cannot be located inside the confined space. The stand-by person must check on the well being of the worker inside the confined space every 20 minutes or more frequently if required by the entry procedures.

G9.35 Stand-by person for a moderate hazard atmosphere space

Issued August 1, 1999

A moderate hazard atmosphere confined space requires a stand-by person to be located at or near the entrance. At least every 20 minutes, the standby must visually observe or otherwise check the well being of the workers in the space. The standby can have other duties if they do not interfere with the standby person remaining at or near the entrance to the space, or interfere with the checking of workers in the space. See also OSH Guideline G9.34-1.

G9.36 Stand-by person for a high hazard atmosphere space

Issued August 1, 1999

A high hazard atmosphere confined space requires the stand-by person to be stationed at the entrance to the space and dedicated to the task of monitoring the workers in the space. The standby worker cannot have other duties. See also OHS Guideline G9.34-1.

Back to Top

Guidelines Part 9 - Rescue